Product overview
Low voltage power cables rated 0.6/1 kV are used to distribute electrical power in fixed installations across industrial facilities, commercial buildings, and infrastructure projects.
Available configurations can include copper or aluminum conductors, PVC or XLPE insulation, and optional armoring, depending on the cable design and applicable standard.
Key selection factors: Conductor material, number of cores, cross-sectional area, insulation type, installation method, and mechanical protection requirements.
-
High Temperature Power CableApplication:The main application scenarios of high-temperature power cables are industrial manufacturing, energy systems, civil and construction, special and high-end equipment, and new energy and
-
PVC Flexible Power CableApplication:PVC flexible power cable are suitable for power connection scenarios that require movement, bending, or complex wiring.. . Standard:European Standard: IEC 60227-5:2003 / EN 50525-2-11. .
-
High Flex Power CableApplication:High Flex Power cable are widely used for power connections in equipment such as robots, CNC machine tools, automated production lines, AGV carts, etc.. . Standard:European Standard: IEC
-
LSZH Power CableApplication:Low smoke zero halogen power cables (0.6/1kV) feature fire resistance , low smoke emission, non-toxicity, halogen-free composition, and environmental safety. They are mainly used in
-
Fire Resistant Power CableApplication:Fire resistant power cables (0.6/1kv) have the characteristics of fire resistance, and continuous power supply in case of fire, and are widely used in key fire emergency places such as
-
Rubber Sheathed Power CableApplication:Rubber sheathed power cables have the characteristics of softness, bending resistance, waterproof and wear-resistant, and are suitable for connecting circuits of household appliances,
-
Silicone Rubber Power CableApplication:Silicone rubber power cables (0.6/1kv) have the characteristics of high and low temperature resistance, flexibility, aging resistance and environmental protection, and are suitable for
Cable types & applications
|
Cable type |
Main construction |
Typical application |
|
PVC insulated, non-armored |
Copper or aluminum conductors with PVC insulation and sheath, subject to the specified design |
Fixed indoor wiring in suitable conduits, cable trays, and electrical installations |
|
XLPE insulated, non-armored |
Copper or aluminum conductors with XLPE insulation and an appropriate outer sheath |
Fixed power distribution where the specified cable construction meets installation requirements |
|
XLPE insulated, steel wire armored (SWA) |
XLPE insulation with steel wire armor and an outer sheath, where applicable |
Installations requiring additional mechanical protection, subject to the cable design and installation conditions |
|
XLPE insulated, steel tape armored (STA) |
XLPE insulation with steel tape armor and an outer sheath, where applicable |
Multicore installations requiring mechanical protection against external forces |
Selection note: Suitability for direct burial, outdoor exposure, single-core installations, or specific environmental conditions must be confirmed against the actual cable construction and applicable installation requirements.
Technical specifications
|
Parameter |
Available options / specification |
|
Rated voltage (U₀/U) |
0.6/1 kV |
|
Conductor material |
Copper or aluminum, depending on the selected model |
|
Conductor construction |
Solid or stranded, according to the specified cable design |
|
Conductor cross-sectional area |
Proposed range: 1.5–400 mm²; confirm availability by cable type and core configuration |
|
Number of cores |
Single-core or multicore, subject to product availability |
|
Insulation material |
PVC or XLPE, depending on the selected model |
|
Outer sheath |
PVC or another specified compound, subject to product configuration |
|
Armoring |
Non-armored, SWA, or STA where applicable |
|
Operating temperature |
Depends on the insulation system and applicable product standard; confirm for the selected model |
|
Applicable standard |
To be confirmed for each cable construction and target market |
Technical selection: Current-carrying capacity, conductor resistance, short-circuit rating, overall diameter, and minimum bending radius should be confirmed for the selected cable size and installation conditions.

Conductor options: Copper or aluminum conductors can be specified according to electrical design requirements, project standards, and the selected cable construction.
Insulation and sheath: PVC and XLPE are available for different cable designs. Their suitability depends on the required operating conditions and applicable product specifications.
Product standards: IEC 60502-1 may apply to relevant power cable constructions rated up to 1 kV and 3 kV. Other standards, including BS or UL standards, should be specified only where the product design and applicable requirements support them.
Compliance documentation: Applicable declarations, material records, and test reports should be confirmed for the specific product and destination market before ordering.
Customization & OEM/ODM
Cable configuration
Specify conductor material, core count, cross-sectional area, insulation, sheath, and armoring requirements.
01
Technical requirements
Custom designs can be evaluated against project drawings, applicable standards, installation conditions, and specified electrical requirements.
02
Sheath and identification
Color, surface marking, meter marking, and packaging can be discussed according to production capability and order requirements.
03
OEM/private labe
Product identification, packaging, and labeling requirements should be confirmed before production.
04
Electrical testing: Relevant tests may include conductor DC resistance, insulation resistance, and voltage withstand testing, according to the applicable standard and product specification.
Material and dimensional checks: Conductor dimensions, insulation and sheath thickness, and other specified construction parameters can be verified against the agreed requirements.
Type and sample testing: Additional mechanical, thermal, or flame-propagation tests should be selected according to the applicable standard and required approval scope.
Documentation and traceability: Test reports, batch records, and inspection documentation should be agreed upon before ordering. Third-party inspection is subject to project requirements and confirmed arrangements.

Bulk supply & packaging
Drum and reel options
Packaging can be selected according to cable size, order length, handling equipment, and transportation requirements.
Cable protection
End sealing and suitable packaging can be specified to protect the cable during storage and transit.
Delivery planning
Order quantity, production schedule, drum dimensions, shipping method, and destination should be confirmed before order acceptance.
Bulk ordering
For quotations, specify the required cable construction, cross-sectional area, quantity, preferred drum length, and delivery destination.

Request a quote
Send your cable specifications and project requirements for a product configuration and bulk supply quotation.
Information to provide: Cable type, rated voltage, conductor material, core count, cross-sectional area, insulation and sheath requirements, armoring, applicable standard, quantity, drum length, and destination market.
Yangzhou Huayu Cable Co., Ltd. is one of the most professional power cable low voltage manufacturers and suppliers in China, also supports customized service with low price. Please feel free to wholesale advanced power cable low voltage made in China here from our factory. Contact us for pricelist.
Fire Resistant Power Cable, High Flex Power Cable, High Temperature Power Cable