Product overview

 

Low voltage power cables rated 0.6/1 kV are used to distribute electrical power in fixed installations across industrial facilities, commercial buildings, and infrastructure projects.


Available configurations can include copper or aluminum conductors, PVC or XLPE insulation, and optional armoring, depending on the cable design and applicable standard.


Key selection factors: Conductor material, number of cores, cross-sectional area, insulation type, installation method, and mechanical protection requirements.

 
  • High Temperature Power Cable
    Application:The main application scenarios of high-temperature power cables are industrial manufacturing, energy systems, civil and construction, special and high-end equipment, and new energy and
  • PVC Flexible Power Cable
    Application:PVC flexible power cable are suitable for power connection scenarios that require movement, bending, or complex wiring.. . Standard:European Standard: IEC 60227-5:2003 / EN 50525-2-11. .
  • High Flex Power Cable
    Application:High Flex Power cable are widely used for power connections in equipment such as robots, CNC machine tools, automated production lines, AGV carts, etc.. . Standard:European Standard: IEC
  • LSZH Power Cable
    Application:Low smoke zero halogen power cables (0.6/1kV) feature fire resistance , low smoke emission, non-toxicity, halogen-free composition, and environmental safety. They are mainly used in
  • Fire Resistant Power Cable
    Application:Fire resistant power cables (0.6/1kv) have the characteristics of fire resistance, and continuous power supply in case of fire, and are widely used in key fire emergency places such as
  • Rubber Sheathed Power Cable
    Application:Rubber sheathed power cables have the characteristics of softness, bending resistance, waterproof and wear-resistant, and are suitable for connecting circuits of household appliances,
  • Silicone Rubber Power Cable
    Application:Silicone rubber power cables (0.6/1kv) have the characteristics of high and low temperature resistance, flexibility, aging resistance and environmental protection, and are suitable for
 

Cable types & applications

 

Cable type

Main construction

Typical application

PVC insulated, non-armored

Copper or aluminum conductors with PVC insulation and sheath, subject to the specified design

Fixed indoor wiring in suitable conduits, cable trays, and electrical installations

XLPE insulated, non-armored

Copper or aluminum conductors with XLPE insulation and an appropriate outer sheath

Fixed power distribution where the specified cable construction meets installation requirements

XLPE insulated, steel wire armored (SWA)

XLPE insulation with steel wire armor and an outer sheath, where applicable

Installations requiring additional mechanical protection, subject to the cable design and installation conditions

XLPE insulated, steel tape armored (STA)

XLPE insulation with steel tape armor and an outer sheath, where applicable

Multicore installations requiring mechanical protection against external forces

 

Selection note: Suitability for direct burial, outdoor exposure, single-core installations, or specific environmental conditions must be confirmed against the actual cable construction and applicable installation requirements. 

 

Technical specifications

 

Parameter

Available options / specification

Rated voltage (U₀/U)

0.6/1 kV

Conductor material

Copper or aluminum, depending on the selected model

Conductor construction

Solid or stranded, according to the specified cable design

Conductor cross-sectional area

Proposed range: 1.5–400 mm²; confirm availability by cable type and core configuration

Number of cores

Single-core or multicore, subject to product availability

Insulation material

PVC or XLPE, depending on the selected model

Outer sheath

PVC or another specified compound, subject to product configuration

Armoring

Non-armored, SWA, or STA where applicable

Operating temperature

Depends on the insulation system and applicable product standard; confirm for the selected model

Applicable standard

To be confirmed for each cable construction and target market

 

Technical selection: Current-carrying capacity, conductor resistance, short-circuit rating, overall diameter, and minimum bending radius should be confirmed for the selected cable size and installation conditions. 

 

Low Voltage H03Z1Z1H2-F LSZH Flexible Installation Cable

 

Materials & applicable standards

Conductor options: Copper or aluminum conductors can be specified according to electrical design requirements, project standards, and the selected cable construction.


Insulation and sheath: PVC and XLPE are available for different cable designs. Their suitability depends on the required operating conditions and applicable product specifications.


Product standards: IEC 60502-1 may apply to relevant power cable constructions rated up to 1 kV and 3 kV. Other standards, including BS or UL standards, should be specified only where the product design and applicable requirements support them.


Compliance documentation: Applicable declarations, material records, and test reports should be confirmed for the specific product and destination market before ordering.

 

Customization & OEM/ODM

 

Cable configuration

Specify conductor material, core count, cross-sectional area, insulation, sheath, and armoring requirements.

01

Technical requirements

Custom designs can be evaluated against project drawings, applicable standards, installation conditions, and specified electrical requirements.

02

Sheath and identification

Color, surface marking, meter marking, and packaging can be discussed according to production capability and order requirements.

03

OEM/private labe

Product identification, packaging, and labeling requirements should be confirmed before production.

04

 

Quality control & testing

Electrical testing: Relevant tests may include conductor DC resistance, insulation resistance, and voltage withstand testing, according to the applicable standard and product specification.


Material and dimensional checks: Conductor dimensions, insulation and sheath thickness, and other specified construction parameters can be verified against the agreed requirements.


Type and sample testing: Additional mechanical, thermal, or flame-propagation tests should be selected according to the applicable standard and required approval scope.


Documentation and traceability: Test reports, batch records, and inspection documentation should be agreed upon before ordering. Third-party inspection is subject to project requirements and confirmed arrangements.

Low Voltage H05Z1Z1H2-F LSZH Flexible Installation Cable

 

Bulk supply & packaging
 

Drum and reel options

Packaging can be selected according to cable size, order length, handling equipment, and transportation requirements.

Cable protection

End sealing and suitable packaging can be specified to protect the cable during storage and transit.

Delivery planning

Order quantity, production schedule, drum dimensions, shipping method, and destination should be confirmed before order acceptance.

Bulk ordering

For quotations, specify the required cable construction, cross-sectional area, quantity, preferred drum length, and delivery destination.

 

FAQ

 

Q: How do I choose between copper and aluminum conductors?

A: The choice depends on the project design, required electrical characteristics, installation conditions, and applicable standards. Confirm the required conductor material and cross-sectional area before ordering.

Q: What is the difference between SWA and STA cables?

A: SWA uses steel wire armor, while STA uses steel tape armor. Their suitability depends on the cable design, mechanical protection requirements, installation method, and applicable standard.

Q: Can these cables be used for direct burial?

A: Some cable constructions may be suitable for direct burial, but this cannot be assumed for every model. Confirm the cable's construction, sheath properties, and applicable installation requirements.

Q: Can you supply cables to specific standards?

A: Applicable standards and documentation should be confirmed for each requested construction and target market. Provide the required standard and project specification when requesting a quotation.

Q: What information is needed for a quotation?

A: Provide the rated voltage, conductor material, number of cores, cross-sectional area, insulation type, armoring requirement, applicable standard, total length, and delivery destination.

 

modular-1
Request a quote

Send your cable specifications and project requirements for a product configuration and bulk supply quotation.
Information to provide: Cable type, rated voltage, conductor material, core count, cross-sectional area, insulation and sheath requirements, armoring, applicable standard, quantity, drum length, and destination market.

Yangzhou Huayu Cable Co., Ltd. is one of the most professional power cable low voltage manufacturers and suppliers in China, also supports customized service with low price. Please feel free to wholesale advanced power cable low voltage made in China here from our factory. Contact us for pricelist.

Fire Resistant Power Cable, High Flex Power Cable, High Temperature Power Cable
Send Inquiry